Antenna Basics
A half-wave dipole antenna driven at 100 MHz has a physical length of λ/2 = c/(2f) = 3×10⁸/(2×10⁸) = 1.5 m, a radiation resistance of 73 Ω, and a directivity of 1.64 (2.15 dBi). Feed it with a 50Ω coaxial cable and you immediately have a mismatch — that's why half-wave dipoles are often fed via a balun and a matching network. The radiation resistance value of 73Ω is one of the few numbers in antenna theory worth memorising without derivation.
Antenna Gain and Directivity
A Yagi-Uda antenna used for 144 MHz amateur radio with five elements has a gain of around 10 dBi over an isotropic antenna — that 10 dBi means the power density in the main beam direction is ten times what an isotropic radiator would produce with the same input power. Gain and directivity are the two quantities that define how well an antenna concentrates radiated energy, and distinguishing them correctly — including the role of radiation efficiency — is what separates full marks from partial marks in EMT exams.
Electrostatics
Inside a parallel-plate capacitor with plate area A = 0.01 m² and separation d = 1 mm filled with a dielectric of εr = 4, the electric field is uniform at E = V/d = 100 V / 0.001 m = 100 kV/m. That field is the electrostatic quantity that determines breakdown voltage, capacitance (C = ε₀εr·A/d = 354 pF), and the energy stored in the dielectric. Everything in electrostatics — from charge distributions to boundary conditions — ultimately comes down to calculating this field.
EM Wave Propagation
A 1 GHz plane wave incident on a copper surface (σ = 5.8×10⁷ S/m) penetrates only δ = √(2/ωµσ) = √(2/(2π×10⁹ × 4π×10⁻⁷ × 5.8×10⁷)) ≈ 2.1 µm into the conductor. That skin depth of about 2 µm explains why microwave currents flow only on the outer skin of a conductor, why hollow waveguides work, and why RF engineers plate conductors with silver rather than using solid gold — skin depth at 1 GHz in silver is about 2.2 µm.
Faraday's Law
In a 50 Hz transformer with a core flux of Φm = 0.05 Wb, the secondary winding of 200 turns generates an RMS EMF of exactly 4.44 × 50 × 200 × 0.05 = 2220 V — that number comes directly from Faraday's Law applied to a sinusoidally varying flux. The same law governs the voltage induced in a rectangular loop moving through a non-uniform magnetic field, the back-EMF of a DC motor, and the signal picked up by an inductive proximity sensor near a moving steel gear.
Gauss Law
When you need to find the electric field inside a coaxial cable with inner conductor radius a = 2 mm and outer conductor radius b = 8 mm carrying a line charge ρL = 10 nC/m, the direct integration of Coulomb's law is messy — Gauss's Law reduces the problem to a single line of algebra by exploiting cylindrical symmetry. The imaginary cylindrical Gaussian surface enclosing the inner conductor is the key construction, and every EMT exam problem on coaxial lines, spherical charge distributions, and infinite planes uses exactly this approach.
Magnetostatics
A long straight conductor carrying 10 A of DC current produces a magnetic field H = I/(2πr) at radius r — at r = 5 cm, that's H = 10/(2π × 0.05) = 31.83 A/m and B = µ₀H = 4π×10⁻⁷ × 31.83 ≈ 40 µT. That calculation using Ampere's law in integral form is the magnetostatics equivalent of Gauss's law in electrostatics, and it appears in the first ten minutes of every magnetostatics exam paper.
Maxwell's Equations
Before Maxwell added the displacement current term ∂D/∂t to Ampere's law, the law was inconsistent for time-varying fields — applying it to the surface between capacitor plates gave zero enclosed current while the fringing field was clearly non-zero. Maxwell's correction ∇×H = J + ∂D/∂t resolved the inconsistency and simultaneously predicted electromagnetic wave propagation at speed c = 1/√(µ₀ε₀) ≈ 3×10⁸ m/s before Hertz experimentally confirmed it. That single modification connects all of classical electromagnetics.
Smith Chart
When a 50 Ω microstrip line on an FR4 PCB drives a patch antenna with input impedance 73 + j42 Ω at 2.4 GHz, an RF engineer plots the normalised load impedance zL = (73+j42)/50 = 1.46+j0.84 on a Smith Chart and immediately reads off the reflection coefficient magnitude and the stub length needed for matching — no complex arithmetic required. The Smith Chart is a graphical calculator built on the reflection coefficient plane, and once you know how to navigate it, matching problems that would take pages of algebra reduce to a few compass rotations.
Transmission Line Parameters
A 50 Ω coaxial cable like the RG-58 connecting a signal generator to an oscilloscope has its characteristic impedance set by the ratio of its inner and outer conductor diameters — change those dimensions and Z0 shifts. Transmission line parameters are the per-unit-length values of resistance R (Ω/m), inductance L (H/m), conductance G (S/m), and capacitance C (F/m) that together determine how a signal propagates, attenuates, and reflects along the line at frequencies where the wavelength approaches the physical length of the conductor.
Transmission Lines EM
A 50Ω coaxial cable connecting a 50Ω RF source to a 75Ω antenna has a reflection coefficient Γ = (75−50)/(75+50) = 0.2 at the load — 4% of incident power reflects back toward the source. That 4% reflected power is what causes VSWR of 1.5 on the line, and it's exactly why RF engineers obsess over impedance matching; in a 100W transmitter system, 4W returning to the PA can damage the output stage.
Notes